====== Login on LN computer ====== | ====== Login on LN computer ====== | ||
- | The LN computer lives in the GRETINA net and doesn't know | + | The LN computer lives in the GRETINA net and since December 2015 it is accessible from NSCL network |
- | about the outside world. | + | |
* login on gateway machine nsclgw1.nscl.msu.edu | * login on gateway machine nsclgw1.nscl.msu.edu | ||
- | * login as ln on gretina-gln1.nscl.msu.edu | + | * login as ln on gretina-gln1.nscl.msu.edu (35.8.35.167) |
* Remember: "liquid nitrogen two for gretina" | * Remember: "liquid nitrogen two for gretina" | ||
+ | * from a1/a2: ln@gln1 | ||
====== LN scripts ====== | ====== LN scripts ====== | ||
Line 27: | Line 27: | ||
*run-view-master.sh: Output of the LN master process | *run-view-master.sh: Output of the LN master process | ||
- | ====== LN configuration ====== | + | Making long term T plots: |
- | The LN configuration file is found as ~/gln/gln.fig. It is //self-explanatory//. If this file got updated, use run-gln-ui.sh script and the command "load" in there. Note: After a "load" in the UI all detector fill schedules are gone! You need to do a "ton x y z ..." or "fill x y z after h:mm". | + | |
- | ====== ADC to channel mapping ====== | + | *on gln machine go to ~/other/thistory-dev |
- | Documentation for ADC mapping: {{:connections_1_.pdf|}} (OUTDATED, now we have silver boxes) | + | *run there ./run-thistory.sh XXX with the last day as input parameter |
+ | *results th.pdf and d.pdf are written in ~/plots | ||
+ | *uncomment/comment different templates in script for covering different time ranges | ||
- | * ADC 1-4: Manifold overflow 1-4 (Manifold overflow at supply box Q1-Q4) | ||
- | * ADC 11-17: Fill overflow Q1-Q7 (Overflow input at supply box) | ||
- | ^ Quad supply ^ LN ADC ^ LN ADC ^ PreAmp L ^ PreAmp H^ | + | ====== LN configuration ====== |
- | ^ 1 | | | | | | + | The LN configuration file is found as ~/gln/gln.fig. It is //self-explanatory//. If this file got updated, use run-gln-ui.sh script and the command "load" in there. Note: After a "load" in the UI all detector fill schedules are gone! You need to do a "ton x y z ..." or "fill x y z after h:mm". |
- | ^ 2 | 45 | 46 | 48 | 47 | | + | |
- | ^ 3 | 49 | 50 | 51 | 52 | | + | |
- | ^ 4 | 54 | 56 | 53 | 55 | | + | |
- | ^ 5 | 60 | 58 | 57 | 59 | | + | |
- | ^ 6 | 30 | 62 | 63 | 61 | | + | |
- | ^ 7 | 34 | 32 | 33 | 31 | | + | |
- | PreAmp L/H: preamplifier T reading lower/higher T | ||