cobo_frontpanel
Table of Contents
CoBo Front Panel
- 2 Dual VHDCI Connectors (LVDS,LVCMOS3.3V) (compatible cable Amphenol CS-VHDCIMX200-003)
- 2 Dual LEMO Connectors (LVCMOS 3.3V/TTL 5V) LEMO EPY.00.250.NTN.
- 1 Micro-USB (USB UART) (compatible cable Molex 0687840001)
- 4×4 LEDS (X0 LEDs are for Asad0, X1 LEDs are for Asad1, etc)
- P = Asad Plugged
- ON: Asad plugged in
- OFF: No Asad plugged
- Slow Blink: (configuration dependent?)
- Fast Blink: ?
- B = Bad
- ON: Major error. Typically needs user intervention. Power supply error? unresponsive to slow control or reset.
- OFF: no errors
- Slow Blink: Slow control errors e.g. AGET controller busy, etc.
- Fast Blink: bad data frames.
- U = CoBo-Asad Uplink activity i.e. from CoBo to Asad
- ON: ?
- OFF: no activity
- Slow Blink: minor traffic
- Fast Blink: major traffic
- D = CoBo-Asad Downlink activity i.e. from Asad to CoBo
- ON: All or 3 Asads sending data
- OFF: no data from asad
- Slow Blink: slow control replies
- Fast Blink: 2 or less Asads sending data
- 3 MicroTCA LEDS
- Blue = Hot swap
- Green = OK
- Red = Bad
CoBo 0.2v (Prototype)
CoBo 1.0v (Production)
CoBo 0.2v Front Panel (Prototype)
cobo_frontpanel.txt · Last modified: 2014/05/22 10:58 by abunimeh