Opening Target Facility Area
Open
- Turn the Beam/Chopper off
- On the Main Magnets page, turn Dipole D5578 off on BBS/FFS tab; this will take a moment to ramp down to 0 A.
- On the MPS Operator page, turn E-Bends off.
- On the PPS rack, turn the Linac ACS key to Beam Permit.
- On the PPS rack, turn the key for Target RSS Ready For Beam to Off.
- Operator goes to room and starts a survey for entire area, or specific spot if required.
- After room fully surveyed and opened, on the PPS rack, turn the key for the opened room to Regulated Access.
Close
- On the PPS rack, turn the room key to Search Survey.
- Reset the warning alarms in area through the PPS rack.
- Perform search and evict of area.
- Once all target areas are secured, turn the Target RSS Ready for Beam key to Yes. Wait a minute for the Target Facility lights to stop flashing and turn solid red.
- Ensure you are in required machine mode for beam.
- Turn the Linac ACS key back to Beam Permit.
- On the Main Magnets page, cycle the D5578 dipole to 90 A on the BBS/FFS tab:
- Copy the current setpoint value.
- Turn on D5578 dipole (this will take a few seconds to go green).
- When the dipole is on, input 90 A into the setpoint value.
- When done ramping to 90 A, paste the original setpoint value.
- Wait for dipole to ramp to original value.
- On the MPS Operator page, turn the E-Bends on.
- On the Main Magnets page check that the E-Bends setpoint and readback values match on the V-LEBT tab.
- On the MPS Operator page, set configuration according to MPS Device Configuration Guideline.
- Check and clear all set MPS devices.
- Start the Chopper.