task:k500_changingbetweenbeamswithinacocktail
This is an old revision of the document!
Changing Between Beams Within A Cocktail
Beams changes within a cocktail may be completed quickly by changing the main field of the cyclotron and a limited number of changes to other beamline devices. The intention is to change the least number of devices while producing the same beam quality delivered to SEE.
Steps:
- Run main probe in to 24“
- This process could be done on FC2007, as long as the beam intensities for all beam species is within acceptable levels
- Increase chopper duty cycle to 100%
- Set the main field epsilon value to the new value
- If the value is already logged/known, use that. Otherwise use the value from Analog Beams and add the offset for the pilot. e.g. Pilot is at -300 ppm, new beam expected at +5000 ppm, set field to +4700 ppm
task/k500_changingbetweenbeamswithinacocktail.1751979381.txt.gz · Last modified: 2025/07/08 08:56 by lange