Recovering HPECR from Gate Valves Closing

If MPS tripped due to gate valves closing, please follow the HPECR recovery instructions:

  • On HPECR operator page, Open Gate Valve FE_ISRC2:BGV_D0675.
  • Go to Microwave Amp. in the 18GHz Microwave Transmitter section.
  • On the Microwave Amp page:
    1. Check on HPECR Vacuum page and ensure that the BCCG's are okay
    2. Reset all interlocks / safety interlocks
    3. Turn on PLC commands
    4. Reset all interlocks / safety interlocks again
    5. Turn on BEAM power supply ISC2_HVP_D0652 & ISC2_HVP_D0677
    6. Turn back on the acceleration column puller PSEL D0678.
    7. Reset “RF OUTPUT Set point” to ZERO
    8. Turn ON RF output
    9. Recover the RF output power to where it was by 100V/step.
task/hpecr_recovery.txt · Last modified: 2025/03/18 17:03 by painter