====== Responding to SRF cavity trips ====== - Determine which cavity has tripped - MPS failed device dialogue box - RF main page or any cavity status page - Navigate to the LLRF interlock detail page - If any of the following interlocks are present do not reset the latch or the cavity, skip directly to last step. See image below - PLC - Spark Detectors - Excessive Cavity Field - Tuner Fault - CCG Low/High - Bias Tee Low/High - If the cavity is interlocked on something other than the above list reset the interlock and restart the cavity - If the cavity trips off again or trips off on Cavity Field Low you may have to perform a reduce recover on the surrounding cavities. If cavity trips off again skip to last step - Call SRF personnel on call ===== Links/Media ===== * [[https://portal.frib.msu.edu/sites/accsystems/preoperation/_layouts/15/WopiFrame2.aspx?sourcedoc=%7bEEE947E8-4FAA-47DB-BBAB-4FAE59CD87ED%7d|SRF call list]] * {{task:srf_marked_interlock.png}}