======= Opening Target Facility Area ======= == Open == - Turn the Beam/Chopper off - On the Main Magnets page, turn Dipole D5578 off on BBS/FFS tab; this will take a moment to ramp down to 0 A. - On the MPS Operator page, turn E-Bends off. - On the PPS rack, turn the Linac ACS key to Power Permit. - On the PPS rack, turn the key for Target RSS Ready For Beam to Off. - Operator goes to room and starts a survey for entire area, or specific spot if required. - After room fully surveyed and opened, on the PPS rack, turn the key for the opened room to Regulated Access. == Close == - On the PPS rack, turn the room key to Search Survey. - Reset the warning alarms in area through the PPS rack. - Perform search and evict of area. - Once all target areas are secured, turn the Target RSS Ready for Beam key to Yes. Wait a minute for the Target Facility lights to stop flashing and turn solid red. - Ensure you are in required machine mode for beam. - Turn the Linac ACS key back to Beam Permit. - On the Main Magnets page, cycle the D5578 dipole to 90 A on the BBS/FFS tab: - Copy the current setpoint value. - Turn on D5578 dipole (this will take a few seconds to go green). - When the dipole is on, input 90 A into the setpoint value. - When done ramping to 90 A, paste the original setpoint value. - Wait for dipole to ramp to original value. - On the MPS Operator page, turn the E-Bends on. - On the Main Magnets page check that the E-Bends setpoint and readback values match on the V-LEBT tab. - On the MPS Operator page, set configuration according to MPS Device Configuration Guideline. - Check and clear all set MPS devices. - Start the Chopper. ====SN==== *good page, could benefit from some "why's" but I can see that being ideally on another adjacanet page or something ===== Links ===== * [[clist>154|Search-and-Evict Procedure for the FRIB Target Hall]] * [[dcc>WBS=S30103&Sub=RC&SN=008105|MPS Device Configuration Guideline]]