====== Performing a CSD ====== * Open the Physapps launcher * Switch to the Apps tab, "All" * Open Charge State Distribution Scan * Select source (selection popup may default to the upper left screen) * Adjust range and gap if desired * Click ''Scan start'' * Do not close the application until the scan is complete * When done, click ''Save the scan'' and save in the default folder ==== Comparing to previous scans ==== ==== Applying correction ==== * Use the cursor to get the position of each oxygen peak on the CSD * Fill in the measured positions in the M/q measured column * Click ''Calc'' to find the correction * Click ''Apply'' to use it ==== SN ==== * Correction info is vague and needs expanding on, this would heavily improve with a "why" page, but that's a different issue ==== Showing reference lines ====