| Line 5: | Line 5: | ||
| - Insert Viewer D2569 on the FSEE GUI. | - Insert Viewer D2569 on the FSEE GUI. | ||
| - On the viewer page, set the status to Live. Then start the chopper and put beam on the viewer. | - On the viewer page, set the status to Live. Then start the chopper and put beam on the viewer. | ||
| - | - Select the n value to begin accumulating points, up to about 10, then pause. | + | - Select the cumulative average |
| - Open the slice view tab under option. | - Open the slice view tab under option. | ||
| - | - On the side, change X value to rectangle. Drag the cursor on the viewport to place a rectangle onto where the beam is. This will give you the uniformity measurement. | + | - On the side, change |
| - | - Then click the arrow button on the bottom right of the screen. | + | - Then click the arrow button on the bottom right of the screen, which will update the uniformity for the users. |
| - Once this is done, go ahead and take out the viewer and put FC_D2569 back into the beamline. | - Once this is done, go ahead and take out the viewer and put FC_D2569 back into the beamline. | ||
| - Put beam back onto the cup and wait a second. Then you'll click, on the bottom right corner of the FSEE GUI page, the Send flux o users / Calibrate Jaws button. | - Put beam back onto the cup and wait a second. Then you'll click, on the bottom right corner of the FSEE GUI page, the Send flux o users / Calibrate Jaws button. | ||
| - Once this is done, stop beam and the uniformity measurement will be done. | - Once this is done, stop beam and the uniformity measurement will be done. | ||