   - Insert Viewer D2569 on the FSEE GUI.   - Insert Viewer D2569 on the FSEE GUI.
   - On the viewer page, set the status to Live. Then start the chopper and put beam on the viewer.    - On the viewer page, set the status to Live. Then start the chopper and put beam on the viewer. 
-  - Select the n value to begin accumulating points, up to about 10, then pause. +  - Select the cumulative average n value to begin accumulating points, up to about 10, then pause. 
   - Open the slice view tab under option.   - Open the slice view tab under option.
-  - On the side, change X value to rectangle. Drag the cursor on the viewport to place a rectangle onto where the beam is. This will give you the uniformity measurement. +  - On the side, change evaluation parameter from X to rectangle. Drag the cursor on the viewport to place a rectangle onto where the beam is. This will give you the uniformity measurement. 
-  - Then click the arrow button on the bottom right of the screen. +  - Then click the arrow button on the bottom right of the screen, which will update the uniformity for the users
   - Once this is done, go ahead and take out the viewer and put FC_D2569 back into the beamline.    - Once this is done, go ahead and take out the viewer and put FC_D2569 back into the beamline. 
   - Put beam back onto the cup and wait a second. Then you'll click, on the bottom right corner of the FSEE GUI page, the Send flux o users / Calibrate Jaws button.    - Put beam back onto the cup and wait a second. Then you'll click, on the bottom right corner of the FSEE GUI page, the Send flux o users / Calibrate Jaws button. 
   - Once this is done, stop beam and the uniformity measurement will be done.    - Once this is done, stop beam and the uniformity measurement will be done. 
task/uniformity_measurement.1752957413.txt.gz · Last modified: 2025/07/19 16:36 by painter