task:search_evict
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| task:search_evict [2025/09/09 04:48] – Added "and authorized" to the staffing requirements. Also added radios to the equipment sections. look | task:search_evict [2025/09/25 01:55] (current) – look | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== Search and Evict ====== | ====== Search and Evict ====== | ||
| - | {{tag> | ||
| Before beam can be sent into an area that has been previously open to workers, operators must secure this area and evict any personnel found in the area. This is to prevent unnecessary exposure from beam induced radiation or, in certain areas like the FRIB linac tunnel, from x-ray radiation. | Before beam can be sent into an area that has been previously open to workers, operators must secure this area and evict any personnel found in the area. This is to prevent unnecessary exposure from beam induced radiation or, in certain areas like the FRIB linac tunnel, from x-ray radiation. | ||
| Line 14: | Line 13: | ||
| * Enterprise Competency: Perform an FRIB Tunnel Search and Evict | * Enterprise Competency: Perform an FRIB Tunnel Search and Evict | ||
| * Staffing: Minimum of two (2) fully trained and authorized personnel | * Staffing: Minimum of two (2) fully trained and authorized personnel | ||
| - | * Equipment: Validated Linac Tunnel ACS, hardhat, inspection mirror (optional), radio | + | * Equipment: Validated Linac Tunnel ACS, hardhat, inspection mirror (optional), padlock/key #48, radio |
| - | * Documentation: | + | * Documentation: |
| ==== Target Hall (B605A & B605) ==== | ==== Target Hall (B605A & B605) ==== | ||
| Line 22: | Line 21: | ||
| * Staffing: Minimum of two (2), at least one of whom is fully trained and authorized | * Staffing: Minimum of two (2), at least one of whom is fully trained and authorized | ||
| * Equipment: Validated Target Facility ACS, hardhat, safety glasses, radio | * Equipment: Validated Target Facility ACS, hardhat, safety glasses, radio | ||
| - | * Documentation: | + | * Documentation: |
| ==== VPS & ARIS ==== | ==== VPS & ARIS ==== | ||
| Line 28: | Line 27: | ||
| * Enterprise Competency: Perform an FRIB VPS Search and Evict | * Enterprise Competency: Perform an FRIB VPS Search and Evict | ||
| * Staffing: Minimum of one (1) fully trained and authorized person | * Staffing: Minimum of one (1) fully trained and authorized person | ||
| - | * Equipment: Validated Target Facility ACS, radio, padlocks | + | * Equipment: Validated Target Facility ACS, radio, padlocks/keys #26, #27, #28, and #57 |
| - | * Documentation: | + | * Documentation: |
| ==== Transfer Hall (1500TH) ==== | ==== Transfer Hall (1500TH) ==== | ||
| Line 36: | Line 35: | ||
| * Staffing: Minimum of one (1) fully trained and authorized person | * Staffing: Minimum of one (1) fully trained and authorized person | ||
| * Equipment: Validated Transfer Hall ACS, radio | * Equipment: Validated Transfer Hall ACS, radio | ||
| - | * Documentation: | + | * Documentation: |
| ==== Mechanical Areas ==== | ==== Mechanical Areas ==== | ||
| Line 44: | Line 43: | ||
| * Enterprise Competency: FRIB Mechanical Room 1603 Search-and-Evict | * Enterprise Competency: FRIB Mechanical Room 1603 Search-and-Evict | ||
| * Staffing: Minimum of two (2) personnel, one of whom is fully trained and authorized | * Staffing: Minimum of two (2) personnel, one of whom is fully trained and authorized | ||
| - | * Equipment: Padlocks | + | * Equipment: Padlocks/Keys #3 and #57, radio |
| - | * Documentation: | + | * Documentation: |
| === NCU Rooms (B601, SB601, & SB602/ | === NCU Rooms (B601, SB601, & SB602/ | ||
| Line 51: | Line 50: | ||
| * Enterprise Competency: FRIB NCU Rooms (B601, SB601, and SB602/ | * Enterprise Competency: FRIB NCU Rooms (B601, SB601, and SB602/ | ||
| * Staffing: Minimum of two (2) personnel, one of whom is fully trained and authorized | * Staffing: Minimum of two (2) personnel, one of whom is fully trained and authorized | ||
| - | * Equipment: Padlocks | + | * Equipment: Padlocks/Keys #3 and #57, radio |
| - | * Documentation: | + | * Documentation: |
| ==== Experimental Vaults ==== | ==== Experimental Vaults ==== | ||
| === N4 === | === N4 === | ||
| + | |||
| + | * Enterprise Competencies: | ||
| + | * Unsecure/ | ||
| + | * Act as Qualified For Task (QFT) worker, DC systems | ||
| + | * Staffing: Minimum of one (1) fully trained and authorized person | ||
| + | * Equipment: Validated N4 ACS, Personal HV LOTO Padlock, radio | ||
| + | * Documentation: | ||
| + | * [[https:// | ||
| + | * [[https:// | ||
| === S1 === | === S1 === | ||
| - | * Enterprise Competency: Perform | + | * Enterprise Competency: Perform |
| * Staffing: Minimum of one (1) fully trained and authorized person | * Staffing: Minimum of one (1) fully trained and authorized person | ||
| * Equipment: Validated S1 ACS, radio | * Equipment: Validated S1 ACS, radio | ||
| - | * Documentation: | + | * Documentation: |
| === S2/S3 === | === S2/S3 === | ||
| * Enterprise Competency: Perform an S2/S3 Experimental Vaults Search-and-Evict | * Enterprise Competency: Perform an S2/S3 Experimental Vaults Search-and-Evict | ||
| - | * Staffing: Minimum of two (2) personnel, one of whom is fully trained | + | * Staffing: Minimum of two (2) personnel |
| - | * Only one (1) fully trained person | + | |
| * Equipment: Validated S2/S3 ACS, radio | * Equipment: Validated S2/S3 ACS, radio | ||
| - | * Documentation: | + | * Documentation: |
| ===== ReA ===== | ===== ReA ===== | ||
| Line 77: | Line 84: | ||
| ==== ReA3 RFQ Area ==== | ==== ReA3 RFQ Area ==== | ||
| - | * Enterprise Competency: | + | * Enterprise Competency: |
| - | * Staffing: | + | * Staffing: |
| - | * Equipment: | + | * Equipment: |
| - | * Documentation | + | * Documentation: [[https:// |
| ==== ReA3 SRF Area ==== | ==== ReA3 SRF Area ==== | ||
| - | * Enterprise Competency: | + | * Enterprise Competency: |
| - | * Staffing: | + | * Staffing: |
| - | * Equipment: | + | * Equipment: |
| - | * Documentation | + | * Documentation: [[https:// |
| - | + | ||
| - | ==== ReA3 Experimental Vault??? ==== | + | |
| ==== ReA6 Accelerator Vault ==== | ==== ReA6 Accelerator Vault ==== | ||
| - | * Enterprise Competency: | + | * Enterprise Competency: |
| - | * Staffing: | + | * Staffing: |
| - | * Equipment: | + | * Equipment: |
| - | * Documentation | + | * Documentation: [[https:// |
| ==== ReA6 Experimental Vault ==== | ==== ReA6 Experimental Vault ==== | ||
| - | * Enterprise Competency: | + | * Enterprise Competency: |
| - | * Staffing: | + | * Staffing: |
| - | * Equipment: | + | * Equipment: |
| - | * Documentation | + | * Documentation: [[https:// |
| ===== K500 ===== | ===== K500 ===== | ||
| Line 112: | Line 117: | ||
| * Staffing: Minimum of one (1) fully trained and authorized person | * Staffing: Minimum of one (1) fully trained and authorized person | ||
| * Equipment: Validated K500 ACS, portable O< | * Equipment: Validated K500 ACS, portable O< | ||
| - | * Documentation: | + | * Documentation: |
| ==== User Vault (1500P/P1) ==== | ==== User Vault (1500P/P1) ==== | ||
| Line 119: | Line 124: | ||
| * Staffing: Minimum of one (1) fully trained and authorized person | * Staffing: Minimum of one (1) fully trained and authorized person | ||
| * Equipment: Validated K500 ACS, radio | * Equipment: Validated K500 ACS, radio | ||
| - | * Documentation: | + | * Documentation: |
task/search_evict.1757407692.txt.gz · Last modified: 2025/09/09 04:48 by look
