User Tools

Site Tools


task:k500_qtkm

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
task:k500_qtkm [2025/07/08 10:05] langetask:k500_qtkm [2025/07/08 10:07] (current) lange
Line 19: Line 19:
  
 === Knob Rate === === Knob Rate ===
-The rate that the knobs adjust devices settings may be controlled by right clicking on the "S" field. This brings up a dialog box where the rate can be modified. Electrostats whose settings are ~10000 V will need a higher knob rate (100), and devices with low settings like corrector magnets at 0.5 amps will need a lower rate (0.1)+The rate that the knobs adjust devices settings may be controlled by right clicking on the "S" field. This brings up a dialog box where the rate can be modified. Electrostats whose settings are ~10000 V will need a higher knob rate (100), and devices with low settings like corrector magnets at 0.5 amps will need a lower rate (0.1). If you are tuning a device and it requires numerous turns of the knob to see a change in beam, you may need to increase the knob rate. If the knob is too sensitive, lower the rate.
task/k500_qtkm.1751983548.txt.gz · Last modified: 2025/07/08 10:05 by lange