| Line 13: | Line 13: | ||
| - Set the beam intensity to acceptable levels using chopper | - Set the beam intensity to acceptable levels using chopper | ||
| - Extract the probe and send beam to FC2007 | - Extract the probe and send beam to FC2007 | ||
| - | - Tweak the dee voltages. May also tweak centering/ | + | - Make additional adjustments to a minimal amount of devices. Observations have shown that the D0864 dipole will need to be adjusted, possibly the D0899 dipole |
| - Send beam to end of SEE line FC2192 | - Send beam to end of SEE line FC2192 | ||
| - This may be done with small beam or uniform beam | - This may be done with small beam or uniform beam | ||
| - | - Adjust HEBT dipoles (D???? and D????) to maximize current on FC2192 | + | - Adjust HEBT dipoles (D2048 and D2060) to maximize current on FC2192 |
| - Set up uniform beam | - Set up uniform beam | ||