User Tools

Site Tools


task:k500_changingbetweenbeamswithinacocktail

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
task:k500_changingbetweenbeamswithinacocktail [2025/07/08 09:21] langetask:k500_changingbetweenbeamswithinacocktail [2025/08/07 18:47] (current) lange
Line 9: Line 9:
   - Set the main field epsilon value to the new value   - Set the main field epsilon value to the new value
     - If the value is already logged/known, use that. Otherwise use the value from Analog Beams and add the offset for the pilot. e.g. Pilot is at -300 ppm, new beam expected at +5000 ppm, set field to +4700 ppm     - If the value is already logged/known, use that. Otherwise use the value from Analog Beams and add the offset for the pilot. e.g. Pilot is at -300 ppm, new beam expected at +5000 ppm, set field to +4700 ppm
-  - Set the MHB phase 1 phase to the new value if known +  - Set the MHB F1 phase to the new value if known 
-    - If value is not known, maximize beam current on probe by adjusting MHB phase 1 phase.+    - If value is not known, maximize beam current on probe by adjusting MHB F1 phase.
   - Set the beam intensity to acceptable levels using chopper   - Set the beam intensity to acceptable levels using chopper
   - Extract the probe and send beam to FC2007   - Extract the probe and send beam to FC2007
-  - Tweak the dee voltagesMay also tweak centering/extraction bump but this may not be necesary+  - Make additional adjustments to a minimal amount of devicesObservations have shown that the D0864 dipole will need to be adjusted, possibly the D0899 dipole
   - Send beam to end of SEE line FC2192   - Send beam to end of SEE line FC2192
     - This may be done with small beam or uniform beam     - This may be done with small beam or uniform beam
-  - Adjust HEBT dipoles (D???? and D????) to maximize current on FC2192+  - Adjust HEBT dipoles (D2048 and D2060) to maximize current on FC2192
   - Set up uniform beam   - Set up uniform beam
task/k500_changingbetweenbeamswithinacocktail.1751980883.txt.gz · Last modified: 2025/07/08 09:21 by lange

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki