| task:fs1_charge_selection [2025/08/06 08:21] – Added reference image of initial email for FS1 slit setting instructions. Moved updating the post-Strip charge state to the Selecting Charge States Section. look | task:fs1_charge_selection [2025/08/06 10:59] (current) – Removed work in progress. Added the needs review tag for anyone to suggest improvements. look | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | **WORK IN PROGRESS** | ||
| - | |||
| ====== Changing Post-Stripper Charge States ====== | ====== Changing Post-Stripper Charge States ====== | ||
| + | {{tag> | ||
| On rare occasions, the Fragment Separator physicists will request that the FS1 charge selecting slits be moved to allow/block certain charge states after the charge stripper. The controls for the FS1 charge selecting slits can be found by going to Diag. Launcher -> Charge Selector. The slits can be configured by adjusting the slit center and slit gap motors to send only one charge state or many charge states. After configuring the slits, it will be necessary to measure and update the stripping efficiency for the loss monitors and the records of the Fragment Separator physicists (they sometimes ask for this value). Once this is done, beam can be sent to them again. | On rare occasions, the Fragment Separator physicists will request that the FS1 charge selecting slits be moved to allow/block certain charge states after the charge stripper. The controls for the FS1 charge selecting slits can be found by going to Diag. Launcher -> Charge Selector. The slits can be configured by adjusting the slit center and slit gap motors to send only one charge state or many charge states. After configuring the slits, it will be necessary to measure and update the stripping efficiency for the loss monitors and the records of the Fragment Separator physicists (they sometimes ask for this value). Once this is done, beam can be sent to them again. | ||
| Line 13: | Line 11: | ||
| - Set the slit gap to 15 mm and wait for the slits to stop moving. | - Set the slit gap to 15 mm and wait for the slits to stop moving. | ||
| - Select the desired charge state and hit the ' | - Select the desired charge state and hit the ' | ||
| - | - In the Threshold Configuration Tool (TCT), update the charge state being sent by clicking the 'AP Config.' | + | - In the TCT, update the charge state being sent by clicking the 'AP Config.' |
| The slits should be in the correct position for the charge state after they have finished moving. | The slits should be in the correct position for the charge state after they have finished moving. | ||
| + | |||
| + | ==== Things to Keep in Mind ==== | ||
| + | * Most of the charge state buttons for the primary beam species are to only send that specific charge state. The only exception (as of August 08, 2025) is the ' | ||
| + | * While there are no formal instructions to send multiple (but not all) charge states, we could potentially calculate the slit gap and center based on a single charge state gap of 15 mm and the use of the charge state centers. | ||
| + | * To find the position of the left slit, subtract 15/2 mm from the slit center of the left most charge state of interest (the more negative the center, the more left the charge state is in the beamline). To find the position of the right slit, add 15/2 mm to the slit center of the right most charge state of interest (the more positive the center, the more right the charge state is in the beamline). We can then calculate the gap and center from: '' | ||
| + | * Example: Want to send only the 74+ and 75+ charge states of 238U. The respective centers are 10.5 mm and -1.1 mm. If we assume that each charge state needs a 15 mm gap, then the left slit should be at '' | ||
| + | * For sending multiple charge states, we could probably just take the average of the states and then use that as the post-Strip charge state. AP might use a weighted average, but this should be close enough. | ||
| + | * **When in doubt, call AP about what to set the slits to.** | ||
| ===== Measuring the Stripping Efficiency ===== | ===== Measuring the Stripping Efficiency ===== | ||
| Line 34: | Line 40: | ||
| Some of the information on setting the FS1 slits was taken from an email from July 11, 2025. A screenshot of this email is posted below. | Some of the information on setting the FS1 slits was taken from an email from July 11, 2025. A screenshot of this email is posted below. | ||
| - | {{ : | + | {{ : |
task/fs1_charge_selection.1754482917.txt.gz · Last modified: 2025/08/06 08:21 by look