+ | ====== Sending beam to a new destination ====== | ||
+ | |||
+ | |||
+ | ==== Steps ==== | ||
+ | |||
+ | * Check the MPS Device Configuration Guideline for power limits and special notes | ||
+ | * Calculate beam power with the [[phys_calc|physics calculator]] | ||
+ | * Configure chopper | ||
+ | * [[mps_config|Configure MPS]] | ||
+ | * Coordinate with AP for whether cavities need monitoring | ||
+ | * Calculate thresholds in Diag MPS page | ||
+ | * [[task: | ||
+ | * Configure DCCTs if needed | ||
+ | * [[task: | ||
+ | * Set beam inhibit mode | ||
+ | * Send beam | ||
+ | |||
+ | ==== Notes From Shane :)==== | ||
+ | * phys calc isn't really necessary with the beam power calc on MPS operator, worth a mention and probably easier to use for newer operator | ||
+ | * Also the importance of double checking Energy and Stripping eff especially would be a good tip | ||
+ | * note that cw is 100hz, 9950us | ||
+ | * wouldn' | ||
+ | * You don't calculate anything in the Diag page, do you mean 5521 and Scott' | ||
+ | * DCCTs are only for going past the target, generally I'd leave that as a separate section as you otherwise need to get into the weeds with checking the ARIS post etc. | ||
+ | * I'd probably do inhibit modes earlier, not a huge issue but similar to prev notes it's a bigger issue that I think could use more detail | ||
+ | |||
+ | |||