 ==== Disclaimer ==== ==== Disclaimer ====
 While the setting of DCCTs is referenced in several procedures, there is no official guideline for what to set them to.  The instructions below are just what has somehow become common practice. While the setting of DCCTs is referenced in several procedures, there is no official guideline for what to set them to.  The instructions below are just what has somehow become common practice.
 +
 +==== Where to Find the DCCTs ====
 +  * FRIB Homepage, Diag Launcher, Under "Engineering/Expert Pages", DCCTs
  
 ==== Current practice ==== ==== Current practice ====
 Currently operators are setting the DCCTs using the following steps: Currently operators are setting the DCCTs using the following steps:
-  - Disarm DCCT, note the magnet setpoint+  - Disarm DCCT_D1064, note the magnet setpoint
   - Set the negative and positive thresholds to 0.2% pf current magnet setpoint   - Set the negative and positive thresholds to 0.2% pf current magnet setpoint
   - Clear the DCCT alarm, arm the DCCT   - Clear the DCCT alarm, arm the DCCT
  
 +{{:task:dccts.png?1200|}}
  
 ==== Setting the values ==== ==== Setting the values ====
Line 19: Line 23:
   * [[ops>FRIB FTC DCCT Operation.pdf|DCCT Operation instructions]]   * [[ops>FRIB FTC DCCT Operation.pdf|DCCT Operation instructions]]
   * [[info:dcct_info]]   * [[info:dcct_info]]
 +
  