| Line 16: | Line 16: | ||
| ===Tips/ | ===Tips/ | ||
| * When taking the Linac RSS out of Beam Permit, it is good practice to block beam upstream of the E-Bends and then turn off their power supplies before turning the key in the PPS rack. | * When taking the Linac RSS out of Beam Permit, it is good practice to block beam upstream of the E-Bends and then turn off their power supplies before turning the key in the PPS rack. | ||
| - | * The controls for the E-Bend power supplies can be on found various pages. The most common page used by operators to turn the E-Bends on and off can be found by going to 'FRIB Launch Page' -> 'MPS Operator' | + | * The controls for the E-Bends' |
| * When trying to turn the E-Bend power supplies back on after a period of not being in Beam Permit, wait ~10-15 seconds after the Beam Permit LED on the PPS rack has turned solid red before attempting to do so. This will give the PVs time to reconnect to CS Studio and thus be able to receive commands from CS Studio pages. | * When trying to turn the E-Bend power supplies back on after a period of not being in Beam Permit, wait ~10-15 seconds after the Beam Permit LED on the PPS rack has turned solid red before attempting to do so. This will give the PVs time to reconnect to CS Studio and thus be able to receive commands from CS Studio pages. | ||
| * All of the E-Bends power supplies should have similar voltage set point magnitudes with one supply in each pair being negatively biased. | * All of the E-Bends power supplies should have similar voltage set point magnitudes with one supply in each pair being negatively biased. | ||
dev/ebends.1756513983.txt.gz · Last modified: 2025/08/29 20:33 by ryans