User Tools

Site Tools


cobo_changes

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
cobo_changes [2014/05/23 11:33] abunimehcobo_changes [2014/05/23 14:08] (current) abunimeh
Line 19: Line 19:
     * (U36), (U38), and (U39) Switching regulators have updated hole sizes for better fitting     * (U36), (U38), and (U39) Switching regulators have updated hole sizes for better fitting
     * (SW2) HDT001 switch layout fixes     * (SW2) HDT001 switch layout fixes
-  * Clocking (see [[cobo_clocking|CoBo Clocking]]) +  * Changed Clocking (see [[cobo_clocking|CoBo Clocking]]) 
-    * CKR traces from PLL to LVDS buffer and from LVDS buffer to VHDCI connector are now equal +    * CKRs traces from PLL to LVDS buffer and from LVDS buffer to VHDCI connector are now equal 
-    * CKW traces from PLL to LVDS buffer and from LVDS buffer to VHDCI connector are now equal  +    * CKWs traces from PLL to LVDS buffer and from LVDS buffer to VHDCI connector are now equal  
-    * CLKin1 no longer uses MCH clock. A dedicated oscillator is now used (X9)+    * On LMK04800 (U41) CLKin1 no longer uses MCH clock as an input. A dedicated oscillator is now used (X9) 
 +    * re-arranged outputs on LMK04800 (U41) 
 +  * Consistent labeling and naming scheme on Front panel 
 +  * Move usb-uart (J3) foward i.e. closer to front panel 
 +  * USB-UART (U60) is power thru USB 
 +  * Add 0 ohm resistors between MAX3378EEUD+ and FPGA (LEMO) 
 +  * Radianheatsinks [[http://www.radianheatsinks.com/Products/INH35001-18/2.6_493.aspx|INH35001-18/2.6K29+T710]] is now used for Virtex-5
cobo_changes.1400859238.txt.gz · Last modified: 2014/05/23 11:33 by abunimeh