cobo_changes [2014/05/23 11:29] abunimehcobo_changes [2014/05/23 14:08] (current) abunimeh
Line 17: Line 17:
   * Mutant WSCA/SYNC signal is now on a CC pin   * Mutant WSCA/SYNC signal is now on a CC pin
   * Footprint updates   * Footprint updates
-    * U36, U38, and U39 Switching regulators have updated hole sizes for better fitting +    * (U36)(U38), and (U39Switching regulators have updated hole sizes for better fitting 
-    * HDT001 switch layout fixes +    * (SW2) HDT001 switch layout fixes 
-    * +  * Changed Clocking (see [[cobo_clocking|CoBo Clocking]]) 
 +    * CKRs traces from PLL to LVDS buffer and from LVDS buffer to VHDCI connector are now equal 
 +    * CKWs traces from PLL to LVDS buffer and from LVDS buffer to VHDCI connector are now equal  
 +    * On LMK04800 (U41) CLKin1 no longer uses MCH clock as an input. A dedicated oscillator is now used (X9) 
 +    * re-arranged outputs on LMK04800 (U41) 
 +  * Consistent labeling and naming scheme on Front panel 
 +  * Move usb-uart (J3) foward i.e. closer to front panel 
 +  * USB-UART (U60) is power thru USB 
 +  * Add 0 ohm resistors between MAX3378EEUD+ and FPGA (LEMO) 
 +  * Radianheatsinks [[http://www.radianheatsinks.com/Products/INH35001-18/2.6_493.aspx|INH35001-18/2.6K29+T710]] is now used for Virtex-5
cobo_changes.1400858996.txt.gz · Last modified: 2014/05/23 11:29 by abunimeh