This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
to-do_list [2015/10/26 16:04] pereira [In data U6] |
to-do_list [2023/10/19 17:15] (current) swartzj |
||
|---|---|---|---|
| Line 7: | Line 7: | ||
| * [[Installation FP SCI|Install the focal-plane scintillator]] with the right thickness (1mm or 5mm) | * [[Installation FP SCI|Install the focal-plane scintillator]] with the right thickness (1mm or 5mm) | ||
| - | * Ensure that the object scintillator is in good conditions | + | * Ensure that the object scintillator is in good condition |
| * [[Turning magnets on off#Arming of Dump Switch|Arm dump switches]] | * [[Turning magnets on off#Arming of Dump Switch|Arm dump switches]] | ||
| Line 19: | Line 19: | ||
| * Make sure Intermediate PPACs have gas | * Make sure Intermediate PPACs have gas | ||
| - | ===== In data U6 ===== | + | ===== In data U4 ===== |
| - | * Start [[Software#u6pc5 (data U6)|Software applications]] (in computer | + | * Start [[Software#u4pc8 (data U4)|Software applications]] (in computer |
| - | * Source the environment file to run the DAQ: | + | ==== Setting up DAQ software ==== |
| - | * Open a terminal in u6pc5 and type '' | + | |
| - | * Type '' | + | |
| - | * Verify that **stagearea** in u6pc5 is pointing to the right place. After typing '' | + | * For each experiment, an S800 Device Physicist will, after backing up whatever |
| - | * Create a experiment directory in **/ | + | |
| - | * Go to the newly created experiment directory, and create subdirectories **s800built**, | + | |
| - | * Create the stagearea link by typing '' | + | |
| - | * Run the S800 DAQ with multilogger enabled, | + | |
| + | === Backup any updates === | ||
| + | |||
| + | * ~/ | ||
| + | * Compare files in the subdirectory Configurations (e.g. '' | ||
| + | * Manually add the modified files and commit the changes, and '' | ||
| + | |||
| + | === Uninstall existing files === | ||
| + | |||
| + | * '' | ||
| + | * '' | ||
| + | |||
| + | === Install existing files === | ||
| + | |||
| + | * '' | ||
| + | * The script should relink **stagearea** to the right place, provided that the proper experimental number is given. After typing '' | ||
| + | |||
| + | === Set S800 DAQ mode === | ||
| + | |||
| + | * Set S800 DAQ in [[s800 daq tools# | ||
| + | |||
| * Check [[s800 daq tools# | * Check [[s800 daq tools# | ||
| + | ===== Other items ===== | ||
| * [[Turning magnets on/off#Set magnet currents individually |Put 10 Amps in Spectrograph dipoles]] | * [[Turning magnets on/off#Set magnet currents individually |Put 10 Amps in Spectrograph dipoles]] | ||
| Line 44: | Line 59: | ||
| * [[Magnetic-rigidity setting|Set spectrograph Brho]] (coordinate with experimenters) | * [[Magnetic-rigidity setting|Set spectrograph Brho]] (coordinate with experimenters) | ||
| + | |||
| + | |||
| + | |||
| + | |||
| + | ===== At the end of the experiment ===== | ||
| + | * Verify with S800 Device Physicist that S800 DAQ software is uninstalled. This can be done by typing script '' | ||
| + | |||
| + | * Unbias detectors, CRDC interface boards, CRDCs gate, etc | ||
| + | |||
| + | * [[Gas handling system|Remove gas]] from CRDCs and Ion Chamber | ||