====== Cosmic Enthusiasts ====== | ====== Cosmic Enthusiasts ====== | ||
+ | My institution holds an Early AP program starting August 20, 2012. To excite my students about Physics I showed the Youtube video "Small Matter and Big Science" (short film). | ||
+ | Manju P. | ||
==== The Cosmic Enthusiasts ==== | ==== The Cosmic Enthusiasts ==== | ||
{{:2012_research:trio4.jpg|}} | {{:2012_research:trio4.jpg|}} | ||
- | ===== Question? ========== | + | ===== Our Question: Are cosmic radiation levels higher during the day than at night? ====== |
- | ** Are cosmic radiation levels higher during the day than at night? ** | + | |
Line 20: | Line 22: | ||
=====Scintillator Similar to One Used===== | =====Scintillator Similar to One Used===== | ||
{{: 2012_research:detector.jpg|frame|Scintillator Similar to One Used}} | {{: 2012_research:detector.jpg|frame|Scintillator Similar to One Used}} | ||
- | ==== | + | |
- | Problems with the Scintillator ==== | + | ==== Problems with the Scintillator ==== |
It should be noted that we had these problems with the scintillator... | It should be noted that we had these problems with the scintillator... | ||
- | * Unordered List Itemduring the in-class experiment... a loose upper paddle | + | * during the in-class experiment... a loose upper paddle |
- | * Unordered List Item073112 4:00 PM.When beginning the experiment... a lower paddle that didn't work.. | + | * 073112 4:00 PM.When beginning the experiment... a lower paddle that didn't work.. |
- | * Unordered List Item2nd device obtained...A lower paddle that didn't work after 3 trials... continued with upper paddle reading | + | * 2nd device obtained...A lower paddle that didn't work after 3 trials... continued with upper paddle reading |
- | * Unordered List Item073112 9:00 PM After 3 trials the upper paddle began taking data at a much quicker rate. Continued taking 10 trials. Then switched to coincidence. Took 4 trials of good information. Then machine began acting erratically again. | + | * 073112 9:00 PM After 3 trials the upper paddle began taking data at a much quicker rate. Continued taking 10 trials. Then switched to coincidence. Took 4 trials of good information. Then machine began acting erratically again. |
- | * Unordered List Item080112 5:00AM After 5 trials with coincidence, the machine began erratically. Paddles were readjusted. Trial 11's upper panel seemed to be reading too low. | + | * 080112 5:00AM After 5 trials with coincidence, the machine began erratically. Paddles were readjusted. Trial 11's upper panel seemed to be reading too low. |
===== | ===== | ||
Line 43: | Line 45: | ||
{{:2012_research:experimental_4.jpg?300|}} | {{:2012_research:experimental_4.jpg?300|}} | ||
- | **A closeup highlighting the foiled covered scintillator panels** | + | **A close-up highlighting the foiled covered scintillator panels** |