This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
group_secar2.0 [2018/09/13 16:28] wagner [Optics misalignments] |
group_secar2.0 [2018/09/13 16:49] (current) plastun |
||
|---|---|---|---|
| Line 12: | Line 12: | ||
| {{ : | {{ : | ||
| ====Understanding COSY Matrix output==== | ====Understanding COSY Matrix output==== | ||
| - | Command: OV 1 1 0 ; {order 1, phase space dim 1 INCLUDING ENERGY, # of parameters 0}\\ | + | Command: |
| + | < | ||
| Output:\\ | Output:\\ | ||
| |1.0|0.0|0.0|0.0|-0.41| | |1.0|0.0|0.0|0.0|-0.41| | ||
| Line 36: | Line 37: | ||
| With the spot size on the target, designed to be ±0.5 mm (1σ), the anglular spread then is ±15 mrad.\\ | With the spot size on the target, designed to be ±0.5 mm (1σ), the anglular spread then is ±15 mrad.\\ | ||
| Adding the calculated spread from the reaction with the target of 0.13 deg = ±2.26 mrad we get ±17.26 mrad of angular spread.\\ | Adding the calculated spread from the reaction with the target of 0.13 deg = ±2.26 mrad we get ±17.26 mrad of angular spread.\\ | ||
| - | ⇒COSY beam input: SB 0.0005 **0.01726** 0 0.0005 **0.01726** 0 0 0.0047 0 0 0 ;\\ | + | ⇒COSY beam input: |
| + | < | ||
| Output for this beam passing the dipole: | Output for this beam passing the dipole: | ||
| {{ : | {{ : | ||
| Line 187: | Line 189: | ||
| </ | </ | ||
| {{ : | {{ : | ||
| - | One can see how Wien filter cleans the recoils from the projectile beam. | + | One can see how Wien filter cleans the recoils from the projectile beam at FP2. |
| ---- | ---- | ||
| - | THANK YOU FOR VISITING OUR PAGE | + | ====== |